Copper-nickel (CuNi, also called cupronickel) is the standard material for seawater piping, condensers, heat exchangers and firemains. The two grades most often specified are CuNi 90/10 (UNS C70600) and CuNi 70/30 (UNS C71500). Both resist seawater corrosion and biofouling. The main differences are strength, the flow velocity each can handle, and cost.
CuNi 90/10 vs 70/30 at a glance
| Property | CuNi 90/10 (C70600) | CuNi 70/30 (C71500) |
|---|---|---|
| Nickel (%) | 9.0 to 11.0 | 29.0 to 33.0 |
| Iron (%) | 1.0 to 1.8 | 0.4 to 1.0 |
| Manganese (%) | 1.0 max | 1.0 max |
| Copper | Balance | Balance |
| Typical tensile strength (annealed) | about 275 MPa | about 360 MPa |
| EN designation | CuNi10Fe1Mn, CW352H | CuNi30Mn1Fe, CW354H |
| Relative cost | Lower | Higher (three times the nickel) |
Strength
The extra nickel makes 70/30 noticeably stronger than 90/10. That is why navies have traditionally used 90/10 for surface ships and 70/30 for submarines, where higher pressures need the stronger alloy. For most surface and onshore seawater systems, 90/10 has enough strength and is the economical choice.
Seawater velocity limits
Both alloys form a thin protective film in seawater, with general corrosion rates of about 0.0025 to 0.025 mm per year. That film is only stable below a design flow velocity. Above it, erosion corrosion starts, especially downstream of bends, tees and flanges. 70/30 tolerates higher velocities than 90/10. Typical design guidelines are:
| Service | 90/10 (m/s) | 70/30 (m/s) |
|---|---|---|
| Condensers and heat exchangers, once-through | 2.4 | 3.0 |
| Condensers and heat exchangers, two-pass | 2.0 | 2.6 |
| Piping up to 76 mm ID, long-radius bends | 2.5 | 2.8 |
| Piping 77 to 99 mm ID, long-radius bends | 3.2 | 3.5 |
Source: Copper Development Association design guidelines. Larger pipe diameters allow higher velocities. Your piping designer should confirm the limit for each line size.
Where each grade is used
- CuNi 90/10 (C70600): seawater cooling and firewater piping, ship and offshore piping systems, desalination plant piping, condenser and heat exchanger tubes, hull sheathing and splash-zone cladding.
- CuNi 70/30 (C71500): high-velocity condenser tubes, heat exchangers in power plants and MSF desalination, high-pressure seawater lines, pump and valve parts, and hollow bars machined into components that need extra strength.
Standards to specify
Common specifications are ASTM B111 for condenser and heat exchanger tubes, ASTM B466 for seamless pipe, ASTM B467 for welded pipe, ASTM B151 for rod and bar, and ASTM B171 for plate. For offshore 90/10 piping systems, EEMUA 144 (pipes), 145 (fittings) and 146 (flanges) are widely used. In Europe, specify the EN material number (CW352H or CW354H) with the relevant EN product standard.
How to choose
Choose 90/10 for most seawater piping and heat exchangers where velocities stay within the limits above. It costs less and has excellent resistance to biofouling. Choose 70/30 where you need higher strength, higher flow velocity or better erosion resistance, for example in high-velocity condensers or pressure-retaining parts. Both alloys are sensitive to sulphide-polluted water, so pay extra attention to commissioning and to lay-up in polluted harbours.
CuNi 90/10 and 70/30 from JPS Metal & Alloys
We supply CuNi 90/10 and 70/30 round bars, hollow bars, plates, seamless pipes and tubes, fittings and flanges from Mumbai, with EN 10204 3.1 mill test certificates and optional third-party inspection. We export to the GCC, Europe, Singapore and the USA. Send your grade, size and quantity for a quote.