Flanges connect pipes, valves, pumps and vessels so that a line can be assembled, inspected and taken apart. Choosing the right type depends on pressure, temperature, fluid, and how often the joint will be opened.
| Flange type | How it fits | Best for |
|---|---|---|
| Weld neck | Long tapered hub, butt welded to pipe | High pressure, high temperature, cyclic and hazardous service |
| Slip-on | Slides over the pipe, fillet welded inside and out | Low to medium pressure, easy alignment, lower cost |
| Blind | Solid disc, no bore | Closing pipe ends, vessel nozzles and hydrotest |
| Threaded | Screwed onto pipe, no welding | Small bore lines and areas where welding is unsafe |
| Spectacle (figure 8) | One blind and one open ring on a single plate | Isolating a line for maintenance |
| Orifice | Weld neck, slip-on or threaded with pressure taps | Flow measurement with an orifice plate |
Pressure classes
ASME B16.5 flanges are rated in Class 150, 300, 600, 900, 1500 and 2500. Rating falls as temperature rises, so the class must be checked against the material group and design temperature. As a rough reference, Class 150 carbon steel allows about 20 bar at ambient temperature. EN 1092-1 uses PN ratings such as PN 10, 16, 40 and 100.
Facing types
- Raised face (RF): the most common face, used with spiral wound or sheet gaskets.
- Flat face (FF): used on cast iron and fibreglass equipment to avoid bending the mating flange.
- Ring type joint (RTJ): grooved face for a metal ring gasket in high-pressure and high-temperature oil and gas service.
Materials
Forged flanges are supplied to ASTM A182 in stainless (F304, F316, F321, F347), duplex (F51, F53), and alloy steel (F11, F22, F91), to ASTM A105 in carbon steel, and to ASTM B564 in nickel alloys such as Inconel and Monel. Ask for a 3.1 certificate that includes heat treatment records.
Which one should you pick?
Default to weld neck flanges for process piping above Class 300 or any severe service. Use slip-on flanges for utilities and lower-pressure lines where cost matters. Fit a spectacle blind or a blind flange wherever a section of line must be positively isolated.