Duplex stainless steels have a mixed structure of austenite and ferrite. That structure gives roughly double the yield strength of 304 or 316 together with much better resistance to chloride stress corrosion cracking. Duplex 2205 is the standard grade; super duplex 2507 adds chromium, molybdenum and nitrogen for harsher service.
Composition and PREN
| Property | Duplex 2205 (S32205) | Super Duplex 2507 (S32750) |
|---|---|---|
| Chromium (%) | 22.0 to 23.0 | 24.0 to 26.0 |
| Nickel (%) | 4.5 to 6.5 | 6.0 to 8.0 |
| Molybdenum (%) | 3.0 to 3.5 | 3.0 to 5.0 |
| Nitrogen (%) | 0.14 to 0.20 | 0.24 to 0.32 |
| PREN (typical) | about 35 | 40 or higher |
| Min. yield strength (ASTM A240) | 450 MPa | 550 MPa |
| Min. tensile strength (ASTM A240) | 655 MPa | 795 MPa |
PREN, the pitting resistance equivalent number, is calculated as Cr + 3.3 x Mo + 16 x N. A higher number means better resistance to pitting. Super duplex is defined by a PREN of 40 or more.
Temperature limits
Both grades lose toughness above about 300 degrees Celsius because of 475 degree embrittlement, and they should not be held in the sigma phase range. Most design codes limit duplex to roughly 250 to 300 degrees Celsius. For higher temperatures use austenitic stainless or nickel alloys instead.
Typical applications
- Duplex 2205: pressure vessels, chemical tankers, heat exchangers, pulp and paper, desalination, process piping.
- Super duplex 2507: subsea manifolds, offshore seawater systems, flanges and fasteners, high-chloride process lines, pumps and valves.
Welding and fabrication
Both grades need controlled heat input and matching or over-alloyed filler to keep the ferrite and austenite balance. Super duplex is less forgiving, so qualified procedures and ferrite checks are standard on critical jobs. Specify ASTM A790 or A789 for pipe and tube, ASTM A182 F51, F53 or F55 for flanges and fittings, and ASTM A240 for plate.